ChromaSorb™ Membrane Adsorber

A single-use, membrane-based anion exchanger offering the greatest levels of impurity binding at the highest salt concentrations for MAb and protein purification

Process Economics and Efficiency

       • Eliminate tank capacity constraints
       • Single use device
       • Small manufacturing footprint
       • Linearly scalable family
       • Minimal feedstock used during scaling studies
       • Easy to use

ChromaSorb is an innovative flow-through membrane adsorber designed for the removal of trace impurities includ-ing host cell protein (HCP), DNA, endotoxins and viruses from monoclonal antibody or other protein feedstocks. Unlike traditional anionic resins and membranes, ChromaSorb membrane adsorber provides robust impurity removal over a wider conductivity range. The ability to consistently and reliably perform at greater salt concentrations significantly reduces buffer volumes typically used at this step as well as eliminating tank capacity constraints. This single-use device significantly reduces validation requirements, capital equipment expendi-tures, and time and labor when compared to traditional column based anion exchange resins.

ChromaSorb Device Overview

ChromaSorb Process Development Kit – Blended (CHRFA1BK09)

M9557_023c-16[80078-ALL].jpg

       • ChromaSorb 0.08 mL devices for process development, optimization or scaling
       • Nine devices manufactured from the same 4 membrane lots (individual devices are each blended with 4 different lots of membrane)

ChromaSorb Process Development Kit (CHRFA1PD09)

M9557_023c-16[80078-ALL].jpg

       • ChromaSorb 0.08 mL membrane-based anion exchanger for process development studies
       • Nine devices from one membrane lot

ChromaSorb Validation Kit (CHRFA1VA09)

M9557_023c-16[80078-ALL].jpg

       • ChromaSorb 0.08 mL membrane-based anion exchanger for lab-scale validation studies
       • Nine devices from 3 different membrane lots

ChromaSorb 50 mL Device

M9557_076-16[80080-ALL].jpg

       • For pilot and medium-volume processing
       • Low hold-up volume
       • 100% integrity tested (aerosol test)
       • Disposable
       • 4 lots of membrane per device

ChromaSorb 500 mL Device

M9557_073C-16[80079-ALL].jpg

       • For large-volume processing
       • Low hold-up volume
       • 100% integrity tested (aerosol test)
       • Disposable
       • 4 lots of membrane per device

Specifications (return to top)

Nominal Membrane Volume0.08 mL device: ~0.08 mL
50 mL device: ~50.3 mL
500 mL device: ~503.0 mL
Permeability1.5 CV/min/psi
BSA Capacity≥50 mg/mL on average at 0 mM NaCl
≥20 mg/mL on average at 280 mM NaCl
Impurity RemovalVirus (MMV): >4 LRV
DNA: >3 LRV
Endotoxin: >3 LRV
Typical Operating Flow Rate0.08 mL device: 1 mL/min (12.5 CV/min)
50 mL device: 650 mL/min (12.5 CV/min)
500 mL device: 6500 mL/min (12.5 CV/min)
Operating BuffersMonovalent buffers only (e.g. Tris and acetate). ChromaSorb membrane adsorber is not recommended for use in processes that are in multivalent buffers such as phosphate and citrate as this can lead to reduced capacity.
Feedstock pH RangeTypically 0.5 to 1 pH unit below the pI of the target being purified
Materials of ConstructionMembrane: Ultra High Molecular Weight Polyethylene
Ligand: Primary Amine
Molded parts: High Density Polyethylene


Ordering Information  (return to top)

Select up to 5 products to compare them side by side

Compare Catalogue No. Description Key Applications Qty/Pk  
CHRFA1BK09 ChromaSorb Process Development Kit – Blended Optimization or scaling 9 » Add to Cart
CHRFA1PD09 ChromaSorb Process Development Kit Activity Assay 9 » Add to Cart
CHRFA1VA09 ChromaSorb Validation Kit Validation studies 9 » Add to Cart
CHRFA10050 ChromaSorb 50 mL device Pilot and medium volume 1 » Add to Cart